Bentone B 40 MF

Oil Burner. • Suitable for oils with higher viscosity of both fossil and biological origin. • Equipped with preheater and components suitable for corrosive oils.
238KB Größe 4 Downloads 375 Ansichten
Bentone B 40 MF 6,5-29,5 kg/h (65-295 kW)

Oil Burner •

Suitable for oils with higher viscosity of both fossil and biological origin



Equipped with preheater and components suitable for corrosive oils



Energy saving and compatible with environmental requirements



Designed for easy regulation and maintenance



Designed and approved by the European standard EN 267 together with rapeseed oil according to DIN 51605



Suitable for High Resistance Boilers



Designed for on/off operation



Plug-in contact facilitates the installation

Ölbrenner •

Für flüssige Brennstoffe mit höherer Viskosität geeignet



Ausgerüstet mit Edelstahl-Vorwärmer und Bauteile angepasst für aggressive Brennstoffe



Energiesparend und umweltfreund­lich



Konstruiert für einfache Handhabung bei der Einregulierung und Wartung



Konstruiert und zugelassen nach der europäischen Norm EN 267 bzw. Rapsöl nach DIN 51605



Geeignet für Kessel mit hohen Gegendrücken



Ausführung für 1-Stufen-Betrieb



Eurostecker erleichtert die Installation

Brûleur à fioul •

Adapté à l’utilisation de fioul à haute viscosité d’origine fossile ou biologique



Équipé d’un préchauffeur et de composants pour huiles corrosives



Economise l’énergie et protège l’environnement



Conçu pour être de maniement et de maintenance aisée



Développé et approuvé selon la norme européenne EN267 et huile de colza en accord avec la DIN 51605



Recommandé pour des chaudières fortement pressurisées



Développé pour fonctionnement ON/OF



Prise européenne facilitant l´installation

Type

Typ

Type

Capacity

Leistung

Débit

B 40 MF kg/h

6,5-29,5

kW

65-295

Motor

Motor

Moteur

V/Hz/W

230/50-60Hz/450

Control box

Ölfeuerungsautomat

Coffret de sécurité

Fuel pump

Ölpumpe

Pompe à fuel

Gross weight

Gewicht, brutto

Poids brut

kg c.

50

Volume

Volumen

Volume

m³c.

0,17

Siemens Suntec

mbar

4 3 mbar

2 1 0

220

300 kW

J

H

L

G

GI

I

260

ØC

180

ØD

140

ØD

100

ØC

60

H

E

F

A

B

ØC

A

ØD

E

202

451

160

114

202

K B

gäller ISO 2768-m. Fbearbetade ytor För G H ej toleranssatta mått mellan För ej toleranssatta mått mellan

Designed by

B 40 MF

A B

E

pesven

Approved bybearbetadeDate ytor

Scale gäller ISO 2768-m.

2012-02-28Date 1 : 2,5 pesven This drawing will remain our property and must not without our consent 2012-02-28

526

Designed by

262

316

Approved by

I

J

För övriga mått där tolerans ej angivits gäller  IT15 Surface finish

362 1 : 2,5

Scale

Sign

Modification

Modification message Sign Date

R

Date

*Not suitable for boilers where the front cannot be opened. No.

Modification

Modification message

Sammanställning B45-2U Sammanställning B45-2U R

*Der Brenner ist für Kessel ohne Öffnungsmöglichkeiten der Brennkammertür nicht geeignet. *Non adapté aux chaudières sans trappe frontale.

ØK

ØL

2

M10-12

be copied, shown or given competitors or other unauthorized persons. This drawing will remain our property and must not without our consent be copied, shown or given competitors or other unauthorized persons.

No.

2

För övriga mått där tolerans ej angivits gäller  IT15 Material

115-175

Surface finish

195-245

Material

Replaced/replaced by Replaced/replaced by Drawing no.

Pages

B45U E

F

E

170 055 78. 13-02. Subject to alterations in design. Technische Änderungen vorbehalten. Tous droits de modification réservés

-1

Drawing no.

2

B45U

Pages

2