ñEdition: Hans Turck GmbH & Co.KG ñD-45472 Mülheim an der Ruhr ñWitzlebenstraße 7 ñTel. 0208 4952-0 ñFax 0208 4952-264 ñ
[email protected] ñwww.turck.com
Inductive sensor Bi5U-EM18-AP6X-H1141
M18 x 1 36
24/4 LED
52 9
M12 x 1
●
Threaded barrel, M18 x 1
●
stainless steel, 1.4301
●
factor 1 for all metals
●
degree of protection IP68
●
magnetic field immune
●
extended temperature range
●
high switching frequency
●
3-wire DC, 10…30 VDC
●
normally open, pnp output
●
connector, M12 x 1
Wiring diagram Type Ident-No.
Hysteresis Ambient temperature
5 mm flush ð (0,81 x Sn) mm ð 2% ð ± 10 % ð ± 15 %, ð -25 °C v ï +70 °C 3… 15 % -30…+ 85 °C
Operating voltage Residual ripple
10… 30VDC ð 10 % Uss
DC rated operational current No-load current I0
ð 200 mA ð 15 mA
Residual current Rated insulation voltage Short-circuit protection Voltage drop at Ie
ð 0.1 mA ð 0.5 kV yes / cyclic ð 1.8V
Wire breakage / Reverse polarity protection Output function Insulation class Switching frequency
yes / complete 3-wire, normally open, pnp ÷ ð 2.5 kHz
Housing Dimensions Housing material Material active face Tightening torque of housing nut Connection Vibration resistance Shock resistance Degree of protection
threaded barrel, M18 x 1 52 mm metal, AISI 304 plastic, PBT 25 Nm connectors, M12 x 1 55 Hz (1 mm) 30g (11 ms) IP68
Display switch state
LED yellow
pnp
1 BN
+
3 BU
2
4 BK
3 BU
1 BN 4 BK
Functional principle Inductive sensors are designed for wear-free and non-contact detection of metal objects. Due to a ferrite-less 3-coil system, uprox factor 1 sensors have distinct advantages. They detect all metals at the same switching distance, are magnetic field immune and feature large switching distances.
ñEdition: • 25.11.2008
Rated operating distance Sn Mounting condition Assured sensing range Repeatability Temperature drift
Bi5U-EM18-AP6X-H1141 1635340
Hans Turck GmbH & Co.KG ñD-45472 Mülheim an der Ruhr ñWitzlebenstraße 7 ñTel. 0208 4952-0 ñFax 0208 4952-264 ñ
[email protected] ñwww.turck.com
ñEdition: Hans Turck GmbH & Co.KG ñD-45472 Mülheim an der Ruhr ñWitzlebenstraße 7 ñTel. 0208 4952-0 ñFax 0208 4952-264 ñ
[email protected] ñwww.turck.com
Inductive sensor Bi5U-EM18-AP6X-H1141
Mounting instructions Distance D Distance W Distance T Distance S Distance G
minimum distances 2xB 3 x Sn 3xB 1,5 x B 6 x Sn
Diameter of the active area B
Ø 18 mm
T
G
S D
ñEdition: • 25.11.2008
W
Hans Turck GmbH & Co.KG ñD-45472 Mülheim an der Ruhr ñWitzlebenstraße 7 ñTel. 0208 4952-0 ñFax 0208 4952-264 ñ
[email protected] ñwww.turck.com
ñEdition: Hans Turck GmbH & Co.KG ñD-45472 Mülheim an der Ruhr ñWitzlebenstraße 7 ñTel. 0208 4952-0 ñFax 0208 4952-264 ñ
[email protected] ñwww.turck.com
Inductive sensor Bi5U-EM18-AP6X-H1141
Accessories Type code MW-18
IdentNo. 6945004
Short text
Dimension drawing
mounting bracket; material: stainless steel A2 1.4301 (AISI 304)
19,7
5,5
15,9 19,1 50,8
9,5 25,4 44,5
14,3 1,8
BSS-18
6901320
34,8
7,9
fixing clamp; material: polypropylene 5 26 ø 18 32 30
ñEdition: • 25.11.2008
40,5
Hans Turck GmbH & Co.KG ñD-45472 Mülheim an der Ruhr ñWitzlebenstraße 7 ñTel. 0208 4952-0 ñFax 0208 4952-264 ñ
[email protected] ñwww.turck.com