1-888-80-Titan or 1-888-808-4826. Step 1. Set values for Day and Night temperatures. Step 2. Plug into 120VAC outlet. Pl
934KB Größe 3 Downloads 105 Ansichten
INSTRUCTIONS – REV. B Light sensor (photocell) ®

Photocell

Photo

cell

120 Volts/6 Amps/60Hz

Photocell

120 Volts/6 Amps/60Hz

120 Volts/6 Amps/60Hz

Day temp Mercury 3

Day/Night Fan Speed Controller

Mercury 3 Day/Night Fan Speed Controller

Easy Guide

Me

Day

Mercury 3

rc

/Night

Fan

ur

Spe

ed

y3

Contro

ller

Night temp

Day/Night Fan Speed Controller

Step 2 Step 1

Sensor

Plug into 120VAC outlet Place the sensor at desired location Connect the fan in the front panel outlet Installation is now complete

Set values for Day and Night temperatures

OPTIONAL SETTINGS

B Photocell

Photocell

Mercury 3

Day/Night Fan Speed Controller

B

120 Volts/6 Amps/60Hz

A 120 Volts/6 Amps/60Hz

120 Volts/6 Amps/60Hz

Photocell

A Mercury 3

Day/Night Fan Speed Controller

120 Volts/6 Amps/60Hz

Photocell

B Mercury 3

Day/Night Fan Speed Controller

Mercury 3

Day/Night Fan Speed Controller

Change to Soft Control Mode For medium variation and medium precision; use this mode when equipment turns on and off repeatedly. A. Set both values to minimum B. Plug in, then set both values to maximum within 5 seconds C. Follow instructions as shown in Step 1 & 2

Change to Tight Control Mode For smaller variation and higher precision; use this mode for best performance using correctly sized fan. A. Set both values to maximum B. Plug in, then set both values to minimum within 5 seconds C. Follow instructions as shown in Step 1 & 2

Notes: This unit has been set to perform ‘soft control mode’. For ‘tight control mode’, refer to Optional settings.

®

VANCOUVER, W ASHINGTON U.S.A.

www.titancontrols.net For technical assistance call us at 1-888-80-Titan or 1-888-808-4826.

INSTRUCCIONES - REV. B Sensor de luz (celda fotoeléctrica)

® Photocell

Photo

cell

Controlador de la velocidad del ventilador durante el día/la noche

Guía sencilla

120 Volts/6 Amps/60Hz

Temp. día

120 Volts/6 Amps/60Hz

Mercury 3

120 Volts/6 Amps/60Hz

Photocell

Mercury 3

Day/Night Fan Speed Controller

Me

Day

Mercury 3

rc

/Night

Fan

ur

Spe

ed

y3

Contro

ller

Temp. noche

Day/Night Fan Speed Controller

Paso 2

Sensor Enchufe a un tomacorriente de 120 VAC Coloque el sensor en el lugar deseado Conecte el ventilador en el tomacorriente del panel delantero La instalación se ha completado

Paso 1 Fije los valores para las temperaturas de Día y Noche

CONFIGURACIONES OPCIONALES

B Photocell

Photocell

Mercury 3

Day/Night Fan Speed Controller

B

120 Volts/6 Amps/60Hz

A 120 Volts/6 Amps/60Hz

120 Volts/6 Amps/60Hz

Photocell

A Mercury 3

120 Volts/6 Amps/60Hz

Photocell

Day/Night Fan Speed Controller

B Mercury 3

Day/Night Fan Speed Controller

Mercury 3

Day/Night Fan Speed Controller

Cambio a Modo de control suave

Notas: Esta unidad ha sido configurada para funcionar en “modo de control suave”. Para obtener información sobre el “modo de control ajustado”, consulte la sección de Configuraciones opcionales.

Para una variación media y una precisión media; utilice este modo cuando el equipo se enciende y se apaga repetidamente. A. Fije ambos valores al mínimo B. Enchufe, luego fije ambos valores al máximo en los 5 segundos siguientes C. Siga las instrucciones descritas en el Paso 1 y 2

Cambio a Modo de control ajustado Para una variación más pequeña y una precisión más alta; utilice este modo para obtener un mejor rendimiento utilizando un ventilador del tamaño correcto. A. Fije ambos valores al máximo B. Enchufe, luego fije ambos valores al mínimo en los 5 segundos siguientes C. Siga las instrucciones descritas en el Paso 1 y 2

®

VANCOUVER, W ASHINGTON U.S.A.

www.titancontrols.net Para obtener asistencia técnica, llámenos al 1-888-80-Titan o al 1-888-808-4826.