Lutron Connect Bridge
English 041582a 01/2017
Installation Instructions
Dimensions
Installation
Measurements shown as: in (mm) Top View
CONNECT-BDG2-1 CONNECT-BDG2-2
Accessory Setup Code
CONNECT-BDG2-3 Lutron Connect Bridge
DC Power Adapter
Ethernet Cable
T-5DC-USB-WH (included): CONNECT-BDG2-1 Input: 100 – 240 V~ 50/60 Hz 100 mA; Included (5 V- 300 mA) Output: 5 V- 550 mA
2.75 (69.9)
Not included. Use LPS or SELV output CONNECT-BDG2-2 5 V- 550–1000 mA USB Micro Included (5 V- 300 mA) Connector T-5V-PS-KIT-BL (included): CONNECT-BDG2-3 Input: 100 – 240 V~ 50/60 Hz 300 mA; Included (5 V- 300 mA) Output: 5 V- 1000 mA
Status LED Bar Blink Codes
1. Using the Ethernet cable, connect the Lutron Connect Bridge to a wireless router on the same network (subnet) as the RadioRA 2 main repeater or the HomeWorks QS processor. 2. Attach the DC power adapter cord to the power jack on the Lutron Connect Bridge and insert the DC power adapter plug into a receptacle. 3. Use the RadioRA 2 or HomeWorks QS design software to activate the Lutron Connect Bridge into the system. Ensure convenient access to the “Add” button because it will be used for activating the Bridge into the system and pairing with the Lutron Connect App. 4. Use the Lutron Connect App to control and monitor the system through the Lutron Connect Bridge. The “Add” button will be used for pairing the app to the Bridge. RadioRA 2 Main Repeater
Typical Power Consumption*: 1.3 W
DC Power Adapter
Please Read Before Installing
Lutron Connect App
Lutron Connect Bridge
Use these instructions to install the model numbers listed above. 2.75 (69.9)
For more information visit: www.lutron.com/radiora2 or www.lutron.com/hwqs To obtain the required app, search for “Lutron Connect” in the app marketplace for your smart device.
Ethernet Connection
RadioRA 2 Main Repeater
Front View Status LED Bar
USB
Repeater Status 1
M
2
3
4
Communication RF
Setup
Wired
Test
Wireless Router (not sold by Lutron)
Add
1.19 (30.2) Power Repeater Link COM
N/C
MUX
MUX
9V
1
2
3
4
Integrate RS232
Ethernet Connection
Program / Integrate Ethernet
* Typical Power Consumption test conditions: LED on, Ethernet cable plugged in, powered by the 5 V- adapter. Lutron Electronics Co., Inc. 7200 Suter Road Coopersburg, PA 18036-1299
HomeWorks QS Processor 2.75 (69.9)
DC Power Adapter
Lutron Connect Bridge
Lutron Connect App
Connections Back View “Add” Button Power Jack (to adapter) NEC® Class 2, LPS or SELV, limited energy (