DCID – Dialer Capture Intelligence Device The easy path to GSM and i-GSM communications. ADVANTAGES Honeywell’s Dialer Capture Intelligence Device
Allows Contact ID reporting over a Honeywell GSM or i-GSM communications device.
• Used for control panels that do not support the Honeywell ECP
Universal control panel compatibility (contact ID only).
bus and therefore are not capable of communicating with Honeywell AlarmNet® communication devices over an ECP bus
Simple four-wire ECP connection to the communications device.
• For installations where no phone line service is used for reporting
AlarmNet Communications Device Control Panel or LYNX
GSM Network GPRS data
Protected Premises
AlarmNet Network Control Center
Central Station
Honeywell’s Dialer Capture Intelligence Device
Dialer Capture Intelligence Device model selection:
How It Works • When an event occurs, the control panel goes off hook to dial the central station. The Dialer Capture Intelligence Device detects the off-hook condition and provides the control panel with a dial tone. When the control panel detects the dial tone, it begins dialing the central station phone number. • After the phone number is completed, the Dialer Capture Intelligence Device returns a handshake to the control panel
Automation and Control Solutions Honeywell Security Products Americas 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 1.800.467.5875 www.honeywell.com
Use the DCID model for these control panels: – Honeywell’s L3000 and L5100 – First Alert Professional’s ReadyGD3000 and ReadyGD5100
Use the DCID-EXT model for other control panels.
• The control panel then sends the reports to the Dialer Capture Intelligence Device, which in turn sends them over the ECP bus to the AlarmNet communications device. The Dialer Capture Intelligence Device kisses off each report received successfully from the control panel. • The communications device then transmits the messages to the central station (either over the GSM network or the Internet, as applicable) via AlarmNet
L/DIALNETP/D March 2013 © 2013 Honeywell International Inc.
• When all the reports are sent, the Dialer Capture Intelligence Device goes off hook