Conducell™ 4US Sensors Operating Instructions

Reproduction of any part of this manual in any form whatsoever without the express written consent of Hamilton Bonaduz AG is forbidden. The contents of this ...
1MB Größe 0 Downloads 83 Ansichten
Conducell™ 4US Sensors Operating Instructions Bedienungsanleitung

TABLE OF CONTENTS

Table of Contents 1 Liability .................................................................................. 4 2 Intended use ......................................................................... 5 3 Safety .................................................................................... 5 4 Initial operation ..................................................................... 5 5 Electrical wiring .................................................................... 6 6 Assembly .............................................................................. 8 7 Diagrams with dimensions .................................................. 9 8 Calibration ........................................................................... 10 9 Cleaning ............................................................................... 11 10 Disposal ............................................................................... 11 11 Technical data ..................................................................... 11 12 Instructions for use in potentially explosive atmospheres ...................................................... 12 13 Connection to transmitter ................................................. 13 14 Accessories ........................................................................ 14

Important note Reproduction of any part of this manual in any form whatsoever without the express written consent of Hamilton Bonaduz AG is forbidden. The contents of this manual are subject to change without notice. Technical changes reserved. All efforts have been made to ensure the accuracy of the contents of this manual. However, should any errors be detected, Hamilton Bonaduz AG would greatly appreciate being informed of them. The above notwithstanding, Hamilton Bonaduz AG can assume no responsibility for any errors in this manual or their consequences. Copyright © 2015 Hamilton Bonaduz AG, Bonaduz Switzerland. All rights reserved.

Conducell™ 4US Sensors Operating Instructions

3

LIABILITY

INTENDED USE • SAFETY • INITIAL OPERATION

Operating Instructions

2

These operating instructions are intended for the Hamilton Conducell 4US sensors.

Ref

Description

Thread

ATEX

237700-OP

Conducell 4US-G125

G 11 ⁄4”



237750

Conducell 4US-T150-50

Triclamp 1.5”



237760

Conducell 4US-T150-100

Triclamp 1.5”



Intended use

With the Conducell 4US line, Hamilton has developed a family of in-line conductivity sensors which perform under demanding conditions in biotechnology and the general chemical industry. During development, special attention was paid to an optimum sanitary design. All materials in contact with the solution are FDA approved. The sensors are based on the 4-electrode principle which excludes polarization phenomena normally observed with 2-electrode sensors. The engineered design guarantees an excellent linearity over a conductivity range of more than 6 decades.

3 Safety Hamilton Conducell 4US sensors are quality products manufactured with the latest technology. These instructions should be read, understood and followed by all staff using the device. Hamilton can assume no responsibility for damage and operational disruptions arising from failure to observe these instructions.

This sensor is to be used only as intended and is to be kept in a condition that ensures complete safety. The specifications given in the section “Technical Data” as regards temperature, pressure etc. may under no circumstances be exceeded. Inappropriate use or misuse can be dangerous. Assembly and maintenance may only be done by trained personnel.

1 Liability The Liability of Hamilton Bonaduz AG is detailed in the document “General Terms and Conditions of Sale and Delivery (GTS)”, chapter 12. Hamilton is expressly not liable for direct or indirect losses arising from use of the sensors. It must in particular be insured in this conjunction that malfunctions can occur on account of the inherently limited useful life of sensors contingent upon their relevant applications. The user is responsible for the calibration, maintenance and regular replacement of the sensors. In the case of critical sensor applications, Hamilton recommends using back-up measuring points in order to avoid consequential damages. The user is responsible for taking suitable precautions in the event of a sensor failure.

During assembly, ensure that the positioning is correct and that the O-ring is undamaged. O-rings are consumable items and must be replaced regularly – at least once a year. The built-in temperature sensor should only be used for compensation of conductivity, not for controlling the process temperature. Conducell 4US sensors are used to determine electrolyte conductivity in solutions. If these sensors are used in potentially explosive atmospheres, see the section “Instructions for use in potentially explosive atmospheres”.

4

Initial operation

This Conducell 4US sensor has been carefully tested and is ready for use. During unpacking, please check for any mechanical defects. In case of a complaint please return the Conducell 4US in its original packing to your Hamilton representative and describe the problem.

Conducell™ 4US Sensors Operating Instructions

5

ELECTRICAL WIRING

5

ELECTRICAL WIRING

Electrical wiring

Signal description

Cable Conducell 4US

Pt1000 (low end)

Grey

Pt1000 (low end)

White

Pt1000 (high end)

Blue

Current electrode (high end)

Pink

Potential electrode (high end)

Green

Potential electrode (low end)

Brown

Current electrode (low end)

Yellow

Not connected on sensor

Shield

Not connected

Red

Conducell 4US Emerson 5081 C

Hamilton H100 Cond

Knick Cond 2201 X

Knick Stratos 2401 Cond

Knick Stratos e 2402 / 2405 Cond

Grey D 7 6

D

White D 7 6

D

Blue

E 8 5

E

Pink

1 1 1

1

Green 2 2 2

2

Brown 3 3 3

3

Yellow 4 4 4

4

Shield C 5 5

C

Red

-

Comment

- - -

Short 4 and 5

Short 4 and 5

Short 4 and 5

SIEMENS SIPAN 32/32X

Grey

3 11 23

White

4 11 24

Blue

5 12 25

Pink

8 14 26

Green

11 13 29

Brown

open 15 27

Yellow

open 16 30

Shield

5

Red

- - -

Comment Conducell 4US

Yokogawa Model SC150, SC202, SC402, SC450

2-electrode arrangement

63 Shield *

* For Yokogawa SC150, SC202, SC402, SC450 please be aware that the measuring range must stay within the specified input range of the instrument.

ATTENTION! The linearity of the system is strongly dependent on the instrument to which the sensor is attached. For applicable measuring range refer to Technical Specifications of the manufacturer of the instrument.

Short 4 and 5

Conducell™ 4US Sensors Operating Instructions

7

ASSEMBLY

DIAGRAMS WITH DIMENSIONS

6 Assembly Please check if the process connection is sufficiently clean. Then fit the Conducell 4US. Please follow the instructions mentioned below. Examples: ATTENTION! The cell constant and the linearity of the sensor can vary with the fitting situation. A symmetrical setup is recommended. Leave an open space of 60 mm minimum diameter.

Ø 60mm min

Partitions made of non-conductive material should preferably be used.

Position marker

If the sensor is dismounted, the position marker helps to remount it in the original position.

7

Diagrams with dimensions E = H + 37

Ø 50.5

ATTENTION! A symmetrical setup is recommended in order to ensure a high degree of linearity. To achieve high precision the cell constant should be calibrated in the final setup. Make sure that all 4 electrodes are completely and continuously immersed in the measuring sample.

Ø 24

H*

Ø 50.5 Ø 24

97

50

Ø 13

* H = O-ring position (22 mm ≤ OP ≤ 55 mm)

Conducell™ 4US Sensors Operating Instructions

9

CALIBRATION

CLEANING • DISPOSAL • TECHNICAL DATA

8 Calibration

9 Cleaning

There are two possibilities for calibration:

Conducell 4US can be cleaned with standard cleaning agents. Never use scouring agents which contain hard particles. Please check the O-rings from time to time. When mounting the new O-ring take care not to damage the O-ring nut or the O-ring itself. Otherwise the tightness of seal can no longer be guaranteed.

1) Calibration while sensor is disassembled from process: • First, rinse the sensor thoroughly with deionized water. • Use a beaker or container that has an (internal) diameter of at least 30 mm. (Conducell 4US fits perfectly into the Hamilton Conductivity Standards, and can be calibrated directly in the bottle.) • Use a solution of known conductivity. Check the temperature table of the conductivity standard. • Immerse the lower part of the sensor in the standard. Make sure that the 4 electrodes are completely immersed. The sensor should be placed in the center of the beaker. • Leave the sensor for at least 5 minutes for equilibration, before initiating the calibration on the instrument. For precise determination of the cell constant, it is recommended that you use an assembly situation similar or equal to the situation in the process. The cell constant may vary with the assembly situation.

10 Disposal The design of Hamilton sensors minimizes environmental impact. According to the EU directive 2002/96/EC the Hamilton sensors should be disposed as waste of electrical and electronic equipment, and not in municipal waste, or it can be sent back to Hamilton for disposal.

11 Technical data Measuring Range

0.1 μS/cm to 500 mS/cm

Linearity (relative)

± 0.5 - 5 % 1)

2) Calibration in the process:

Cell constant

0.147 cm-1 2)

• Insert the sensor in the process.

Process Temperature

-20 to 135 °C

Pressure Range

0 to 6 bar

• Leave conductivity and temperature at least 15 min. for equilibration. • Take a process sample and perform an external measurement with a reference conductivity system. The best approach is to perform the measurement at a temperature equal to that of the process. If this is not possible, you need to know the temperature coefficient of your sample (similar to temperature table on Hamilton Conductivity Standards bottle). • Manually adjust the cell constant to read the same conductivity value on the process instrument. • You may switch off the temperature compensation of the process and the laboratory instruments to prevent any errors.

Temperature Sensor Pt1000 Wetted Parts

PEEK (FDA approved), Stainless Steel DIN 1.4435, EPDM (FDA approved)

Surface Quality of Steel

Ra < 0.4 μm (N5)

O-ring Material

EPDM (FDA approved)

Process Connection

G125: G 1-1/4” / T150: Triclamp 1.5”

Electrical Connector

5 m Open End

1) Uncertainty of ± 5 % arise when using only ONE single cell constant for the full range. ± 0.5% accuracy can be achieved when calibration is performed in a conductivity range close to that of the sample. Remember also that linearity is strongly influenced by the transmitter used. 2) Individual cell constant measured with Hamilton standard procedure printed on the label. The cell constant is influenced by the assembly situation.

Conducell™ 4US Sensors Operating Instructions

11

INSTRUCTIONS FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES

CONNECTION TO TRANSMITTER

The conditions described in the ATEX / IECEx certificate must be respected.

ATTENTION! In case a gas atmosphere and a dust atmosphere are or could be present at the same time, the risk of explosion must be examined carefully and special precautions may be necessary.

Assembly 1) The operator of equipment in potentially explosive atmospheres is responsible for ensuring that all components of the system are certified for that area classification and are compatible with each other. Fig. 1: Linearity of the Conducell 4US, connected to a typical process transmitter. One single cell constant determined at 1413 μS/cm was used over the full range.

ATTENTION! The linearity of the system is strongly dependent on the transmitter connected to the sensor.

12 Instructions for use in potentially explosive atmospheres ATEX / IECEx marking: II 1/2 G Ex ia IIB T4/T5/T6 Ga/Gb Gas: CE 0035 II 1/2 D Ex ia IIIC T x °C Da/Db Dust: CE 0035 Manufacturer: Hamilton Bonaduz AG, 7402 Bonaduz, Switzerland EC type examination report: TÜV 03 ATEX 7005 X IECEx certificate of conformity: IECEx TUR 14.0001 X EC type examination report and IECEx certificate of conformity can be downloaded from www.hamiltoncompany.com.

2) In gas atmospheres, the Ex approval is not dependent on any conditions regarding mounting of the sensor. In dust atmospheres, however, special restrictions may apply when using armatures made of plastic material. 3) O-rings having a sealing function between Ex-zone 0 and 1 or Ex-zone 20 and 21, respectively, must be replaced at each dismantling of the sensor. 4) Sensors, transmitter and equipment required are to be set up within one balanced potential system. 5) When the sensor is assembled, the ATEX / IECEx sticker is to be attached to the cable in an easily visible place, as near as possible to the sensor itself. This sticker is to indicate that an ATEX / IECEx approved sensor is in use. The sticker should not be removed at any time.

13 Connection to transmitter Conducell 4US is suitable for connection to an intrinsically safe electrical circuit with protection level ia. The operator of the equipment must ensure that the allowable electrical values for the sensor all exceed those for the transmitter. None of the values cited for electrical power, voltage and current may be exceeded in sum (measurement and temperature circuit together). Electric values for Conducell 4US are as follows: U = 24 V; I = 173 mA; P: Function of process temperature. The maximum allowable electric power P of the transmitter (measurement and temperature circuit together) depends on the desired process temperature.

Conducell™ 4US Sensors Operating Instructions

13

ACCESSORIES

INHALTSVERZEICHNIS

Inhaltsverzeichnis

For gas atmospheres: Type 6

P ≤ 50 mW

P ≤ 100 mW P ≤ 150 mW

T4

109°C

91°C

72°C

T5

74°C

56°C

37°C

T6

59°C

41°C

22°C

1 Haftung ............................................................................... 16 2 Bestimmungsgemässe Verwendung ................................ 17 3 Sicherheitshinweise ........................................................... 17

For dust atmospheres: Table for the calculation of the maximum surface temperature „x“ of the sensor as a function of the maximum electrical power of the transmitter „Pi“ and ambient/process temperatures “Ta”. “x“ has to be smaller than the ignition temperatures of dust involved. Type

P i ≤ 50 mW

P i ≤ 100 mW

P i ≤ 150 mW

6

x = Ta + 21°C

x = Ta + 39°C

x = Ta + 58°C

4 Inbetriebnahme .................................................................. 17 5 Elektrische Anschlüsse ..................................................... 18 6 Einbau des Leitfähigkeitssensors ..................................... 20 7 Masszeichnungen .............................................................. 21 8 Kalibration ........................................................................... 22

Ta: ambient / process temperature

9 Reinigung ............................................................................ 23 10 Entsorgung ......................................................................... 23

The temperature limit stated on the sensor must always be respected.

11 Technische Daten ............................................................... 23 12 Hinweise für den Einsatz in explosionsgefährdeten Bereichen .................................... 24

14 Accessories

13 Montage .............................................................................. 25

Conductivity standards

14 Anschluss an Transmitter .................................................. 26

Value at 25°C Accuracy Stability Certified Package (month) by

Ref

1.3 μS/cm

1%

12

DFM

Glass bottle 300 mL

238973

5 μS/cm

1%

36

DFM

Glass bottle 300 mL

238926

15 μS/cm

1%

36

DFM

Glass bottle 300 mL

238927

84 μS/cm

1%

18

DFM

1 Calpack bottle 500 mL

238984

100 μS/cm

1%

36

DFM

Glass bottle 300 mL

238934

147 μS/cm

1%

18

DFM

1 Calpack bottle 500 mL

238985

706 uS/cm

2%

36

Hamilton

Glass bottle 300 mL

238929

1413 μS/cm

1%

36

DFM

Glass bottle 300 mL

238928

1413 μS/cm

1%

18

DFM

1 Calpack bottle 500 mL

238986

12880 μS/cm

1%

18

DFM

1 Calpack bottle 500 mL

238988

100 mS/cm

1%

24

Hamilton

Glass bottle 300 mL

238935

15 Zubehör ............................................................................... 27

Wichtiger Hinweis Die Reproduktion irgendeines Teils dieses Handbuchs in jeder beliebigen Form ist ohne die ausdrückliche schriftliche Zustimmung der Hamilton Bonaduz AG untersagt. Der Inhalt dieses Hand­ buchs kann ohne vorherige Ankündigung geändert werden. Technische Änderungen vorbehalten. Es wurde grösstmögliche Sorgfalt auf die Richtigkeit der Informationen in diesem Handbuch verwendet. Sollten dennoch Fehler entdeckt werden, würde sich die Hamilton Bonaduz AG freuen, darüber informiert zu werden. Ungeachtet dessen kann die Hamilton Bonaduz AG keine Haftung für etwaige Fehler in diesem Handbuch oder deren Folgen übernehmen. Copyright © 2015 Hamilton Bonaduz AG, Bonaduz Schweiz. Alle Rechte vorbehalten.

Conducell™ 4US Sensoren Bedienungsanleitung

15

BESTIMMUNGSGEMÄSSE VERWENDUNG • SICHERHEITSHINWEISE • INBETRIEBNAHME

HAFTUNG

Bedienungsanleitung

2

Bestimmungsgemässe Verwendung

Mit der Conducell 4US Linie hat Hamilton in-line Leitfähigkeitssensoren entwickelt, welche den strengen Anforderungen in der Biotechnologie und in der chemischen Industrie gewachsen sind. Sie werden für die Bestimmung der elektrolytischen Leitfähigkeit in Lösungen verwendet. Spezielle Aufmerksamkeit während der Entwicklung hat das hygienische Design erhalten. Alle Materialien, welche in Kontakt mit der Messlösung kommen sind FDA geprüft.

Diese Bedienungsanleitung bezieht sich auf die Hamilton Conducell 4US Sensoren.

Ref

Beschreibung

Anschluss ATEX

237700-OP

Conducell 4US-G125

G 11 ⁄4”



237750

Conducell 4US-T150-50

Triclamp 1.5”



237760

Conducell 4US-T150-100

Triclamp 1.5”



Hamilton Leitfähigkeitssensoren sind nach neuesten Erkenntnissen hergestellte Qualitätsprodukte. Diese Betriebsanleitung muss vom zuständigen Personal gelesen, verstanden und beachtet werden. Für Schäden und Betriebsstörungen, die sich aus Nichtbeachten der Betriebsanleitung ergeben, übernimmt die Firma Hamilton keine Haftung.

Die Sensoren sind auf dem 4-Pol Prinzip aufgebaut, welches Polarisierungsphänomene, wie sie bei einer 2-Pol Zelle auftauchen, ausschliesst. Dieses Prinzip garantiert eine exzellente Linearität über den ganzen Linearitätsbereich von 6 Dekaden!

3 Sicherheitshinweise Dieser Sensor ist nur zu benutzen für die bestimmungsgemässe Verwendung und in sicherheitstechnisch einwandfreiem Zustand. Die Spezifikationen bezüglich Druck und Temperatur müssen eingehalten werden (Siehe technische Informationen). Bei Fehlbedienung oder Missbrauch drohen Gefahren. Montage und Wartung dürfen nur durch geschultes Personal vorgenommen werden.

1 Haftung

Beim Einbau muss auf die korrekte Position und auf einwandfreien Zustand des O-Rings geachtet werden. O-Ringe sind Verschleissteile, die regelmässig gewechselt werden müssen, spätestens nach einem Jahr.

Die Haftung der Hamilton Bonaduz AG wird in Kapitel 12 der „Allgemeine Verkaufs- und Lieferbedigungen (AVB)“ geregelt.

Der integrierte Temperaturfühler soll nur für die Kompensation der Leitfähigkeit verwendet werden und nicht für die Steuerung der Prozesstemperatur.

Hamilton haftet insbesondere nicht für direkte oder indirekte Schäden, die sich aus der Nutzung der Sensoren ergeben. Insbesondere ist hier zu beachten, dass Fehlfunktionen durch die naturgemäss applikativ beschränkte Lebensdauer von Sensoren auftreten können. Der Benutzer ist für Kalibration, Wartung und den rechtzeitigen Austausch der Sensoren verantwortlich. Bei kritischen Anwendungen der Sensoren empfiehlt Hamilton redundante Messstellen, um Folgeschäden zu vermeiden. Die Einrichtung geeigneter Absicherungen für den Fall eines Sensorausfalles obliegt dem Anwender.

Die Conducell 4US Sensoren werden eingesetzt zur Bestimmung der elektrolytischen Leitfähigkeit in Lösungen. Werden die Sensoren in explosionsgefährdeten Zonen eingesetzt, so müssen die Hinweise im Kapitel „Hinweise für den Einsatz in explosionsgefährdeten Bereichen“ beachtet werden.

4 Inbetriebnahme Überprüfen Sie den Sensor beim Auspacken auf eventuelle Schäden. Beanstandete Sensoren sind Ihrem Hamilton Partner in der Originalverpackung einzusenden.

Conducell™ 4US Sensoren Bedienungsanleitung

17

ELEKTRISCHE ANSCHLÜSSE

5

ELEKTRISCHE ANSCHLÜSSE

Elektrische Anschlüsse

Signalbeschreibung

Kabel Conducell 4US

Pt1000 (negativ)

Grau

Pt1000 (negativ)

Weiss

Pt1000 (positiv)

Blau

Stromführende Elektrode (positiv)

Rosa

Spannungsabgriff (positiv)

Grün

Spannungsabgriff (negativ)

Braun

Stromführende Elektrode (negativ)

Gelb

Nicht angeschlossen am Sensor

Schirm

Nicht angeschlossen

Rot

Conducell 4US Emerson 5081 C

Hamilton H100 Cond

Knick Cond 2201 X

Knick Stratos 2401 Cond

Knick Stratos e 2402 / 2405 Cond

Grau D 7 6

D

Weiss D 7 6

D

Blau E 8 5

E

Rosa 1 1 1

1

Grün 2 2 2

2

Braun 3 3 3

3

Gelb 4 4 4

4

Schirm C 5 5

C

Rot

-

Kommentar

- - -

4 + 5 brücken

4 + 5 brücken

4 + 5 brücken

SIEMENS SIPAN 32/32X

Grau

3 11 23

Weiss

4 11 24

Blau

5 12 25

Rosa

8 14 26

Grün

11 13 29

Braun

offen 15 27

Gelb

offen 16 30

Schirm

5

Rot

- - -

Kommentar Conducell 4US

Yokogawa Model SC150, SC202, SC402, SC450

2-Elektroden Anordnung

63 Schirm *

* Bitte beachten Sie für Yokogawa SC150, SC202, SC402, SC450 dass der Messbereich der Eingangsspezifikation des Gerätes entspricht.

ACHTUNG! Die Linearität des Systems hängt stark vom Instrument ab, an welches der Sensor angeschlossen ist. Beachten Sie die technischen Spezifikationen des Instrumentenherstellers für den geeigneten Messbereich.

4 + 5 brücken

Conducell™ 4US Sensoren Bedienungsanleitung

19

EINBAU DES LEITFÄHIGKEITSSENSORS

6

MASSZEICHNUNGEN

Einbau des Leitfähigkeitssensors

Bitte kontrollieren Sie, dass die Prozessverbindung sauber ist. Montieren der Conducell 4US und befestigen. Bitte beachten Sie die untenstehenden Instruktionen. Beispiele: ACHTUNG! Die Zellenkonstante und die Linearität kann je nach Einbausituation variieren. Ein symmetrischer Einbau wird empfohlen. Lassen Sie ein Feld von mindestens 60 mm Durchmesser offen.

Ø 60mm min

Verwenden Sie vorzugsweise Wandungen aus nicht leitfähigem Material.

Positionsmarkierung

Die Positionsmarkierung hilft dabei, sicherzustellen, dass ein Sensor immer die gleiche Einbaulage hat.

7 Masszeichnungen E = H + 37

Ø 50.5

ACHTUNG! Um die Linearität zu gewährleisten wird ein symmetrischer Einbau empfohlen. Um eine hohe Präzision zu erreichen, sollte die Zellkonstante im End­ aufbau bestimmt werden. Stellen Sie sicher, dass alle 4 Elektroden komplett und stetig in der zu messenden Lösung eingetaucht sind.

Ø 24

H*

Ø 50.5 Ø 24

97

50

Ø 13

* H = O-Ring Position (22 mm ≤ OP ≤ 55 mm)

Conducell™ 4US Sensoren Bedienungsanleitung

21

REINIGUNG • ENTSORGUNG • TECHNISCHE DATEN

KALIBRATION

8 Kalibration

9 Reinigung

Es gibt zwei Möglichkeiten zu kalibrieren:

Die Conducell 4US kann mit den üblichen Reinigungsmitteln gereinigt werden. Scheuermittel sind ungeeignet. Von Zeit zu Zeit sollten die O-Ringe überprüft werden. Beim Ersatz beschädigter O-Ringe darf die Nut wie auch der neue O-Ring mechanisch nicht verletzt werden, da sonst die Dichtfunktion nicht mehr gewährleistet ist.

1) Kalibrierung ausserhalb des Prozesses: • Zuerst den Sensor gründlich mit deionisiertem Wasser spülen. • Benützen Sie einen Becher mit einem Minimum Innendurchmesser von 30mm. (Die Conducell 4US passt in ein Hamilton Leitfähigkeitsstandard und kann direkt in der Flasche kalibriert werden.) • Brauchen Sie eine Lösung mit einem bekannten Leitfähigkeitsmesswert. Kontrollieren Sie die Temperaturtabelle auf dem Leitfähigkeitsstandard. • Tauchen Sie den unteren Teil des Sensors in die Lösung ein. Stellen Sie sicher, dass die 4 Elektroden komplett eingetaucht sind. Der Sensor sollte in der Mitte des Bechers platziert sein. • Lassen Sie den Sensor für mindestens 5 Minuten in der Messlösung stehen, bis das Gleichgewicht erreicht ist, und starten Sie erst danach die Kalibrierung am Instrument.

10 Entsorgung Das Design der Hamilton Sensoren berücksichtigt bestmöglichst die Umweltverträglichkeit. Gemäss der EU Richtlinie 2002/96/EG müssen Hamilton Sensoren einer getrennten Sammlung für Elektro- und Elektronikgeräten zugeführt werden oder können an Hamilton zur Entsorgung geschickt werden. Sie dürfen nicht dem unsortierten Siedlungsabfall zugeführt werden.

11 Technische Daten

Für eine präzise Bestimmung der Zellkonstante, sollte der Sensor in einer gleichen oder ähnlichen Situation wie im Prozess eingebaut werden. Die Zellkonstante ist von der Einbausituation abhängig.

2) Kalibrierung im Prozess: • Montieren Sie den Sensor im Prozess.

Messbereich

0.1 µS/cm bis 500 mS/cm

Linearität (relativ)

± 0.5 - 5 % 1)

Zellkonstante

0.147 cm-1 2)

Temperaturbereich

-20 bis 135 °C

• Lassen Sie den Sensor stabilisieren für mindestens 15 min.

Druckbereich

0 bis 6 bar

• Nehmen Sie ein Prozessmuster und machen Sie eine externe Referenzmessung. Das beste Messergebnis erhalten Sie, wenn die Messung bei der gleicher Temperatur durchgeführt wird wie im Prozess. Sollte das nicht möglich sein, muss der Temperaturkoeffizient der Messlösung bekannt sein.

Temperatursensor Pt1000

• Manuell die Zellkonstante verstellen, damit der gleiche Leitfähigkeitswert am Prozessinstrument abgelesen wird (ähnlich wie auf der Temperaturtabelle auf den Hamilton Leitfähigkeitsstandards). • Sie können die Temperaturkompensation am Prozess- und Laborinstrument ausschalten, um Fehler zu vermeiden.

Medienberührende Materialien

PEEK (FDA geprüft), Edelstahl DIN 1.4435, EPDM (FDA geprüft)

Oberflächenqualität

Ra < 0.4 μm (N5)

O-Ring Material

EPDM (FDA geprüft)

Prozessanschluss

G125: G 1-1/4” / T150: Triclamp 1.5”

Elektrischer Anschluss

5 m offenes Ende

1) Unsicherheiten von ± 5 % entstehen, wenn eine Zellkonstante über den ganzen Bereich verwendet wird. ± 0.5% Genauigkeiten können erzielt werden, wenn der Messwert der Kalibrierung nahe am Leitfähigkeits­ messwert des Musters liegt. Beachten Sie, dass die Linearität stark vom verwendeten Instrument abhängig ist. 2) Zellkonstante wird von der Einbausituation beeinflusst.

Conducell™ 4US Sensoren Bedienungsanleitung

23

HINWEISE FÜR DEN EINSATZ IN EXPLOSIONSGEFÄHRDETEN BEREICHEN

MONTAGE

Die in der EG-Baumusterprüfbescheinigung bzw. in der IECEx Konformitätserklärung beschriebenen Bedingungen sind einzuhalten.

ACHTUNG! Wenn eine explosionsfähige Gasatmosphäre und eine brennbare Staubatmosphäre zur selben Zeit vorhanden sind oder vorhanden sein dürfen, sollte das gleichzeitige Vorhandensein berücksichtigt werden und bedarf zusätz­ licher Schutzmassnahmen.

13 Montage Fig. 1: Linearität einer Conducell 4US, angeschlossen an ein typisches Prozessmessgerät. Mit einer einzigen Zellkonstante, welche bei 1413 μS/cm bestimmt wurde, wurde über den ganzen Bereich gemessen.

ACHTUNG! Die Linearität des Systems ist stark vom verwendeten Instrument abhängig.

12 Hinweise für den Einsatz in explosionsgefährdeten Bereichen ATEX / IECEx Kennzeichnung: II 1/2 G Ex ia IIB T4/T5/T6 Ga/Gb Gas: CE 0035 II 1/2 D Ex ia IIIC T x °C Da/Db Staub: CE 0035

1) Der Betreiber einer Anlage in explosionsgefährdeten Zonen ist dafür verantwortlich, dass alle Komponenten des Systems für die jeweilige Zoneneinteilung zertifiziert sind und untereinander kompatibel sind. 2) Der Einsatz des Sensors in einer Gasatmosphare ist an keine Bedingungen bezüglich des Einbaus des Sensors gebunden. Bei einer Staubatmosphare hingegen sind Einschränkungen zu beachten bei Verwendung von Armaturen aus Kunststoff. 3) Jene O-Ringe, die eine dichtende Funktion zwischen Ex-Zone 0 und 1 bzw. 20 und 21 übernehmen, müssen bei jedem Ausbau der Elektrode ersetzt werden. 4) Die Sensoren, die Leitungswege und die dazugehörigen Betriebsmittel sind innerhalb eines einzigen Potentialausgleichsystems zu errichten. 5) Bei der Montage des Sensors muss das beiliegende ATEX / IECEx Kennzeichnungsschild an gut sichtbarer Stelle am Kabel befestigt werden, möglichst nahe beim Sensor. Dieses Schild soll darauf hinweisen, dass ein ATEX / IECEx zugelassener Sensor montiert ist. Es darf nicht entfernt werden.

Hersteller: Hamilton Bonaduz AG, CH-7402 Bonaduz, Switzerland EG-Baumusterprüfbescheinigung: TÜV 03 ATEX 7005 X IECEx Konformitätserklärung: IECEx TUR 14.0001 X EG-Baumusterprüfung und IECEx Konformitätserklärung können über www.hamiltoncompany.com heruntergeladen werden.

Conducell™ 4US Sensoren Bedienungsanleitung

25

ANSCHLUSS AN TRANSMITTER

ZUBEHÖR

14 Anschluss an Transmitter Conducell 4US ist geeignet zum Anschluss an einen eigensicheren Stromkreis mit Schutzniveau ia. Der Betreiber der Anlage muss sicherstellen, dass die zulässigen elektrischen Werte des Sensors grösser sind als die maximalen Werte des Transmitters. Keiner der angegebenen Werte für Spannung, Strom und Leistung darf in Summe (Mess- und Temperaturstromkreis zusammen) überschritten werden. Die elektrischen Werte für die Conducell 4US sind wie folgt: U = 24 V; I = 173 mA; P: Funktion der Prozesstemperatur. Die maximal zulässige elektrische Leistung P des Transmitters (Mess- und Temperaturstromkreis zusammen) ist abhängig von der gewünschten Prozesstemperatur. Für Gasatmosphäre: Typ 6

P ≤ 50 mW

P ≤ 100 mW P ≤ 150 mW

T4

109°C

91°C

72°C

T5

74°C

56°C

37°C

T6

59°C

41°C

22°C

15 Zubehör Leitfähigkeitsstandards

Wert bei 25°C Genauig- Stabilität Zertifiziert Verpackungseinheit keit (Monate) vom

Ref

1.3 μS/cm

1%

12

DFM

Glasflasche 300 mL

238973

5 μS/cm

1%

36

DFM

Glasflasche 300 mL

238926

15 μS/cm

1%

36

DFM

Glasflasche 300 mL

238927

84 μS/cm

1%

18

DFM

1 Calpack Flasche 500 mL

238984

100 μS/cm

1%

36

DFM

Glasflasche 300 mL

238934

147 μS/cm

1%

18

DFM

1 Calpack Flasche 500 mL

238985

706 uS/cm

2%

36

Hamilton

Glasflasche 300 mL

238929

1413 μS/cm

1%

36

DFM

Glasflasche 300 mL

238928

1413 μS/cm

1%

18

DFM

1 Calpack Flasche 500 mL

238986

12880 μS/cm

1%

18

DFM

1 Calpack Flasche 500 mL

238988

100 mS/cm

1%

24

Hamilton

Glasflasche 300 mL

238935

Für Staubatmosphäre: Tabelle zur Ermittlung der maximalen Oberflächentemperatur „x“ des Sensors in Abhängigkeit der Leistung des Transmitters „Pi“ und der Prozesstemperatur “Ta”. „x“ muss kleiner sein als die Zündtemperatur des Staubes in der entsprechenden Applikation. Typ

P i ≤ 50 mW

P i ≤ 100 mW

P i ≤ 150 mW

6

x = Ta + 21°C

x = Ta + 39°C

x = Ta + 58°C

Ta: Umgebungs- / Prozesstemperatur

Die auf dem Sensor definierte Temperaturlimite muss in jedem Fall eingehalten werden.

Conducell™ 4US Sensoren Bedienungsanleitung

27

© 2015 Hamilton Bonaduz AG. All rights reserved. 610916/05 —

Web: www.hamiltoncompany.com

800-648-5950 Europe: +41-58-610-10-10

Hamilton Americas & Pacific Rim 4970 Energy Way Reno, Nevada 89502 USA Tel: +1-775-858-3000 Fax: +1-775-856-7259 [email protected]

03/2015

Hamilton Europe, Asia & Africa Via Crusch 8 CH-7402 Bonaduz, Switzerland Tel: +41-58-610-10-10 Fax: +41-58-610-00-10 [email protected]

USA:

To find a representative in your area, please visit hamiltoncompany.com.

This guide may be available in other languages. Visit www.hamiltoncompany.com for more information.